Dungs - Dungs Pressure Switch and Pressure Limiter for gas, air, flue and exhaust gases for DMV safety shutoff valves (USA/CDN)

Dungs


Dungs Pressure Switch and Pressure Limiter for gas, air, flue and exhaust gases for DMV safety shutoff valves (USA/CDN) - GML-A2-4-6

Product Dungs Pressure Switch and Pressure Limiter for gas, air, flue and exhaust gases for DMV safety shutoff valves (USA/CDN)
Brand Dungs
Product Price 0 LKR
Datasheet Download

Description

General

The GAO-, GMH-, and GML-A2… pressure switches are compact, ventless gas  pressure switches for modular valve train components. These pressure switches are suitable for making and/or breaking a circuit when the medium pressure changes  relative to the set point. The set point can be set in the field by an adjustable dial with an integrated scale. The switches incorporate a vent limiter as per UL 353 and limits the escape of gas less than 1.0 CFH of natural gas at 7 PSI if internal switch diaphragm ruptures.

Application

The GAO-, GMH-, and GML-A2… pressure switches are recommended for industrial and commercial heating applications with DMV dual modular valves, SV safety valves, MBC multifunctional controls, and FRI modular pressure regulators. Various mounting options allow direct mounting on the housing. The GAO-, GMH-, and GML-A2… pressure switch is suitable for dry natural gas, propane, butane, air and other inert gases. Suitable for up to 0.1 % by volume, dry H2 S. A “dry” gas has a dew point lower than +15 °F and its relative humidity is less than 60 %.

Specifications

  • Make: DUNGS
  • Part Number: GML-A2-4-6
  • Order Number: 266943
  • Setting range in. W.C: 12.00 -   60.00
  • Max. operating pressure: 7 PSI (500 mbar)
  • Pressure connection: O-ring flange connection on underside of pressure switch
  • Electrical ratings
    • AC eff.  min. 24 V max. 240 V
    • DC   min. 24 V max. 48 V
  • Indication light: 0.30 W energy consumption
  • Electrical connection: Screw terminals via 1/2" NPT conduit connection
  • Enclosure rating: NEMA Type 4
  • Setting tolerance: ±15% switching point deviation referred to set point. Adjusted as pressure rises or as pressure falls, vertical diaphragm position.
  • Vent Limiter: Incorporates a vent limiter as per UL 353 and limits the escape of gas less than 1.0 CFH of natural gas at 7 PSI if internal switch diaphragm ruptures.