Vibrating Level Switches

Endress+Hauser Liquiphant Vibronic point level detector

Available to order MODEL FTL33-AA4M3ACW5J

Liquiphant FTL33 is a point level switch for liquids. The FTL33 is especially designed for food & beverage applications where hygienic requirements are requested. The Liquiphant is used for overfill protection or pump dry-run protection. The IO-Link capability allows easy paramet...

Supplied by FieldInstruments.lk Sri Lanka office · global sourcing network
Delivery time Confirmed with your quotation, based on availability
Freight & applicable duties Extra. Final costs will be provided with your quotation.
Need delivery to another country? Contact us for availability and delivery options.
Contact us

General

Liquiphant FTL33 is a point level switch for liquids. The FTL33 is especially designed for food & beverage applications where hygienic requirements are requested. The Liquiphant is used for overfill protection or pump dry-run protection. The IO-Link capability allows easy parameter setting.

Compact:

  • Smallest vibronic sensor in the market

Safe:

  • Continuous self-monitoring
  • Reliable switching independent of media properties

Easy:

  • - No calibration
  • - Plug & play
  • - IO-Link connectivity

Point level switch in compact design with stainless steel housing.

  • Process connections: Threads
  • Temperature: -40 to +150°C (-40 to +302°F)
  • Pressure: -1 to +40bar (-14.5 to 580psi)
  • Surface roughness: 3.2µm
  • Overfill protection and leakage detection WHG, marine approvals, final inspection report

Features

  • Designed for hygienic applications especially in the food industry - hygienic process connections and approvals available. IO-Link reduces costs and complexity due to easy configuration of the devices via engineering tools
  • CIP and SIP cleanability ensured - up to protection class IP69k
  • Designed according to highest requirements to quality and environmental sustainability, the self-monitoring Liquiphant offers safe switching also in case of power supply loss
  • Independent of changing media properties an accurate switching point is offered
  • A real plug & play sensor is offered without any need for adjustment even with changing media. Measurement is unaffected by conductivity, build-up, turbulence, flows or air bubbles
  • No calibration is required, no specific know-how or tools (e.g. software) necessary
  • Robust design made of stainless steel (316L) assures highest durability - no mechanically moved parts, free of maintenance

Specifications

  • Make: Endress+Hauser
  • Model: FTL33-AA4M3ACW5J
  • Point level detector
  • Media: liquid
  • Output: PNP/3-wire
  • Process connection: G 3/4 (316L)
  • Medium density: > 0.7 g/cm³
  • Power supply: 10–30 V DC
  • Process temperature range: -40–150 °C
  • Process pressure range: -1–40 bar
  • Enclosure material: stainless steel (316L)
  • Protection rating: IP65/IP67
  • Connection: M12 cable gland