General
Minicap FTC260 is a simple and cost-effective rod probe for point level detection in bulk solids, particularly suited to applications involving aggressive media and heavy build-up. It is designed for point level detection of light bulk solids, e.g. grain products, flour, milk powder, animal feed, cement, chalk or gypsum.
For point level detection of light bulk solids, with a grain size up to max. 30mm and a dielectric constant εr ≥ 1.6.
Typical applications: Grain products, flour, milk powder, animal feed, cement, chalk or gypsum.
- Process connection: Threads
- Temperature: -40 to +80°C (-40 to +176°F)
- Pressure: -1 to +25bar (-14.5 to +360psi)
- Sensor length: 140mm (5.51")
- International explosion protection certificates, overfill prevention WHG
Features
- Simple mounting and commissioning without calibration
- Mechanical safety, cost-efficiency and long operating life due to no wearing parts
- High operational safety and reliability due to active build-up compensation
Specifications
- Model: FTC260-BA2H1
- Product type : Point level switch with buildup compensation
- FTC260 : With rod probe for bulk solids and liquids
- Reference operating conditions
- In plastic container:
- Ambient temperature: 23 °C (73 °F)
- Medium temperature: 23 °C (73 °F)
- Medium pressure pe: 0 bar (0 psi)
- Medium: dielectric constant ?r = 2.6
- Conductivity: < 1 μS
- Sensitivity setting: C
- Switch point
- FTC260: Probe center –5 mm (-0.2 in) horizontal, above probe tip 40 mm (1.57 in) vertical
- Power up response
- FTC260: Correct switching after max. 1.5 s
- Long-term drift
- FTC260: 3 mm (0.12 in) horizontal, 6 mm (0.24 in) vertical
- Switching delay when free or covered
- Signal on alarm
- DC, PNP transistor output: <100 μA
- AC / DC, Relay output: relay de-energized
- Material for wetted parts
- Probe FTC260/FTC262: PPS GF40
- FDA: FCN No. 40, 21 CFR 177.1520; Regulation (EC) No. 1935/2004 and No. 10/2011