General
The Prosonic FMU40 sensor is suited for non-contact level measurement in fluids, pastes, coarse bulk material and flow measurement in open channels or at weirs. The two-wire or four-wire compact transmitter can be used in applications with storage tanks, agitators, on stockpiles and conveyor belts. The envelope curve can be shown on the on-site display for simple diagnosis. Linearization function (up to 32 points) for conversion of the measured value into any unit of length, volume or flow rate.
Features
- Reliable non-contact measurement
- Quick and simple commissioning via menu-guided on-site operation with four-line plain text display, 7 languages selectable
- Envelope curves on the on-site display for simple diagnosis
- Hermetically sealed and potted sensor
- Chemically resistant sensor out of PVDF
- Calibration without filling or discharging
- Integrated temperature sensor for automatic correction of the temperature dependent sound velocity
Specifications
- Make : Endress+Hauser
- Model: FMU41-ARB2D2
- Product Type : Ultrasonic Measurement Time-Of-Flight Prosonic FMU41
- Design : FTL50 = Compact
- Certificates : A = Variant for non-hazardous area
- Process connection : R = G 2“ threadISO 228
- Power supply/communication : B = 2 wire, 4...20mA-loop/HART
- Display / on-site operation : 2 = With LC display VU331 incl. on-site operation
- Housing : D = Aluminium T12 housing coated to IP 68 NEMA 6P; with separate terminal compartment; with overvoltage protection
- Screw union/entry : 2 = M20x1.5 screw union
- Weight : 2.6 Kg