General
The GXS Series flame-proof limit switches are designed specifically for use in hazardous applications. The GXS enclosure is epoxy sealed and has an environmental protection of IP66 as per IEC/EN 60529. The entire GXS Series complies with the European Directive on Equipment and Protective Systems Intended for Use in Potentially Explosive Atmospheres (94/9/EC) commonly referred to as the ATEX Directive.
Features
- II 2 G Ex d IIC T6, II 2 D Ex tD A21 IP66 T85°C
- KEMA 00 ATEX 2103 X, IEC Ex KEM 10.0039X
- Conforms to EN60079-0, EN60079-1, EN61241-0, EN61241-1
- CE marked
- EN50041 mounting compatible (GXA Series)
- EN50047 mounting compatible (GXE Series)
- Rugged zinc die-cast housing with epoxy coating
- Pre-wired, 5 m of cable
- Bottom exit cable ONLY
- Double insulated switch element with snap-action basic switch
Specifications
- Make: Honeywell
- Model: GXE51A4J
- Mechanical life: up to 2 million operations
- Degree of protection: IP66, EN 60529
- Operating temperature: @ 3 A-20 °C to 75 °C [-4 °F to 167 °F]
- Operating temperature: @ 4 A-20 °C to 60 °C [-4 °F to 140 °F]
- Standards/approvals: EN60079-0, EN60079-1, EN61241-0, EN61241-1 II 2 G Ex d IIC T6, II 2 D Ex tD A21 IP66 T85°C KEMA 00 ATEX 2103 X; IEC Ex KEM10.0039X (X indicates special conditions for safe use, see certificates for details)
- Electrical rating: AC15, DC13 1NC/1NO change over contacts Double insulated switch element No internal or external earth connection
- Contact material: silver
- Cable/body: Harmonized Cenelec cable, HO5VV-F, 3-core x 0,75 mm2 Black (BK) - common Grey (GY) - NC Brown (BN) - NO Epoxy-sealed cable and body
- Shock: 50 g, IEC 60068-2-27
- Vibration: 10 g, IEC 60068-2-6
fieldinstruments.lk is the leading Instrumentation service provider for process industries and Building automation sector offering branded, high-quality, reliable and effective instrumentation alongside exceptional customer service in Sri Lanka. Apart from this product, you can find wide range of Limit Switches in Sri Lanka from this web site.