Honeywell - Honeywell Smartline STT850-S-0-A-ADB-11C-B-01A0,F1,F5 Temperature Transmitter
Honeywell
Honeywell Smartline STT850-S-0-A-ADB-11C-B-01A0,F1,F5 Temperature Transmitter - STT850-S-0-A-ADB-11C-B-01A0,F1,F5
Product |
Honeywell Smartline STT850-S-0-A-ADB-11C-B-01A0,F1,F5 Temperature Transmitter |
Brand |
Honeywell |
Product Price |
0 LKR |
Datasheet |
Download
|
Description
General
Part of the SmartLine® family of products, the SmartLine STT850 is a high-performance temperature transmitter offering high accuracy and stability over a wide range of process and ambient temperatures. The SmartLine family is also fully tested and compliant with Experion ® PKS providing the highest level of compatibility assurance and integration capabilities. SmartLine easily meets the most demanding needs for temperature measurement applications.
Features
- Digital Accuracy up to +/- 0.10 Deg C for RTD
- Stability up to +/- 0.01% of URL per year for ten years
- 125 mSec update time for single input models
- 250 mSec update time for dual input models
- Built in Galvanic Isolation
- Differential/Averaging/Redundant/Split Range measurements
- Dual Compartment Housing
- Sensor Break detection
- Comprehensive on-board diagnostic capabilities
- Full compliance to SIL 2/3 requirements.
- Available with 15 year warranty
- Supports Namur 107 Extended Diagnostics
- Supports Namur 89 Wire break
- Direct entry of Callendar-Van Dusen coefficients R0, α, δ and β for calibrated RTD sensors (not available on DE units)
Specifications
- Make: Honeywell
- Model: STT850-S-0-A-ADB-11C-B-01A0,F1,F5
- Product type : STT850 Smart Temperature Transmitter
- Input Type : STT850 = Universal Input
- Input Details : S = Single
- Digital output : 0 = No
- Approvals : A = FM Explosion proof, Intrinsically Safe, Non-incendive, & Dustproof
- Electronic Housing Material & Connection Type : A = Polyester Powder Coated Aluminum, 1/2 NPT, Lightning protection
- Output/ Protocol : D = 4-20mA dc, DE Protocol
- Customer Interface Selections : B = Basic indicator, No Config Buttons, English language
- Application Software : 1 = Standard Diagnostics
- 1 = Disabled write protect, High> 21.0mAdc fail mode, Honeywell Std (3.8 - 20.8 mAdc) high and low output limits.
- General Configuration : C = Custom Configuration
- B : Accuracy = Standard, Calibrated Range = Custom (Unit Data Required), Calibration Qty = Single Calibration.
- Mounting Bracket : 0 = None
- Customer Tag : 1 = No customer tag
- Unassembled Conduit Plugs & Adapters : A0 = No Conduit Plugs or Adapters Required
- Certifications and Warranty : F1 = Calibration Test Report & Certificate of Conformance, F5 = Certificate of Origin.