The Johnson Controls F61SD-9175 is a mechanical liquid flow switch designed to monitor low-flow conditions in liquid circulation systems. It uses a T-body construction with a 3/4"-14 NPTF threaded connection and an adjustable flow range of 0.04 to 0.07 dm³/s. The SPDT snap-acting...
General
The Johnson Controls F61SD-9175 is a mechanical liquid flow switch designed to monitor low-flow conditions in liquid circulation systems. It uses a T-body construction with a 3/4"-14 NPTF threaded connection and an adjustable flow range of 0.04 to 0.07 dm³/s. The SPDT snap-acting switch provides electrical switching when liquid flow rises above or falls below the set flow rate. It is suitable for water and ethylene glycol applications and features an IP43 enclosure.
Features
- Mechanical liquid flow switch with T-body design
- Adjustable flow range: 0.04–0.07 dm³/s
- 3/4"-14 NPTF threaded connection
- SPDT snap-acting electrical contact
- Electrical rating: 15(8) A at 230 VAC
- IP43 protection enclosure
- Polycarbonate cover and case
- Brass body construction
- Suitable for water and ethylene glycol
- Paddles supplied separately and not factory-mounted
Key Specifications
Manufacturer: Johnson Controls
Model: F61SD-9175
Product Series: F61
Product Type: Mechanical Liquid Flow Switch
Construction: T-Body
Flow Range: 0.04–0.07 dm³/s
Process Connection: 3/4"-14 NPTF
Contact Type: SPDT Snap-Acting Switch
Electrical Rating: 15(8) A, 230 VAC
Enclosure Protection: IP43 (IP23 without drain plug)
Maximum Liquid Pressure: 20 bar
Maximum Liquid Temperature: 100°C at 20°C ambient
Minimum Liquid Temperature: 0°C
Maximum Ambient Temperature: +55°C
Minimum Ambient Temperature: -40°C
Ambient Humidity: 10–95%
Cover / Case Material: Polycarbonate
Diaphragm: EPDM
Body Material: Brass CuZn40Pb2 (CW617N)
Shipping Weight: 1.0 kg
Applications
- HVAC water circulation systems
- Chilled-water and liquid cooling systems
- Ethylene glycol circulation systems
- Electric immersion heater flow proving
- Pump operation monitoring
- Liquid flow alarm and control applications
Installation Note: The F61SD-9175 is a T-body model. The paddles are supplied separately and are not factory-mounted. The T-body type must not be installed in a vertical pipe. Ensure the flow direction follows the arrow marked on the body.
FieldInstruments.lk
International Inquiries:
Xelexon International (Pvt) Ltd
510, Level 05, Jana Jaya City, Rajagiriya, Sri Lanka 10100
Local Inquiries:
Nexus Engineering Solutions Pvt Ltd
237, Raja Maha Vihara Rd, Mirihana, Pitakotte, Sri Lanka 10100
Testing & Measuring Instruments:
Instrumentation Solutions (Pvt) Ltd
510, Level 05, Jana Jaya City, Rajagiriya, Sri Lanka 10100