Siemens - Siemens Oil Burner Controller

Siemens


Siemens Oil Burner Controller - LAL2.14

Product Siemens Oil Burner Controller
Brand Siemens
Product Price 0 LKR
Datasheet Download

Description

General

Oil burner controls

With or without air pressure supervision for checked air damper control

Flame supervision with

  • photoresistive detector QRB1..., or
  • blue-flame detector QRC1..., or
  • selenium photocell detector RAR...

Uses

  • For the control and supervision of oil atomization burners
  • For burners of medium to high capacity
  • For intermittent operation (at least one controlled shutdown every 24 hours)
  • Can be universally used with multistage or modulating burners
  • Suited for use with stationary air heaters.

Specifications

  • Make:  Siemens
  • Model: LAL2.14
  • Mains voltage:  AC 230 V –15 / +10 % | AC 100 V –15 %...AC 110 V +10 %
  • Mains frequency: 50...60 Hz ±6 %
  • Unit fuse: (built-in) T6,3H250V to DIN EN 60 127
  • Primary fuse: (external) max. 10 A (slow)
  • Flame detectors: QRB1..., QRC1..., RAR...
  • Power consumption approx.: AC 3.5 VA
  • Degree of protection: IP 40, when fitted, with the exception of the connection area (terminal base)
  • Safety class:  II
  • Climatic conditions: class 3K5
  • Mechanical conditions: class 3M2
  • Temperature range: -20...+60 °C
  • Humidity: < 95 % r.h.