General
The CVM-B100 and CVM-B150 units are panel mounted three-phase power analyzers (dimensions: 96×96 and 144×144 mm, respectively). Both offer 4-quadrant measurement (consumption and generation). Suitable for Medium or Low voltage installations, in both 3 or 4-wire three-phase circuits, two-phase circuits with or without neutral, single-phase circuits or ARON connections.
The CVM-B100 and CVM-B150 high-performance units feature a measurement engine that allows the user to analyse many different electrical parameters, in addition to offering a large variety of optional expansion modules for the same unit.
Features
- Format: 96×96 (CVM B100) and 144×144 (CVM B150)
- High-resolution VGA colour screen
- IP 65 front panel protection (with sealing joint)
- 5 voltage inputs (3 phases + neutral + earth) 1000 Vf-f
- 4 Current inputs, ITF
- Class 0.2 voltage and current accuracy
- Class 0.5S energy accuracy
- Expandable unit, up to 4 modules, combining digital and analogue outputs, Modbus/TCP, MBus,
- LonWorks, Profibus, XML/Web
- Modular (optional addition of expansion modules)
- Touch-sensitive movement buttons
- Universal power supply source
- RS485 communications port (Modbus/RTU and BACnet protocols)
- Customisation of parameters to be displayed
- Operating hour indicator for preventive maintenance.
Specifications
- Brand: Circutor
- Model: CVM-B150-ITF-485-ICT2
AC power supply
- Nominal voltage: 100 ... 240 V ~
- Frequency: 45 ... 65Hz
- Consumption: máx. 29.4 VA
- Installation category: CAT III 300 V
DC power supply
- Nominal voltage: 120 … 300 Vdc
- Consumption: max. 11.9 W
- Installation category: CAT III 300 V
Voltage measurement circuit
- Voltage measuring range: 20…600 V~
- Frequency measuring range: 40…70Hz
- Input impedance: 1.2MΩ
- Minimum measurement voltage (Vstart): 10 V~
- Installation category: CAT III 600V
- Maximum input voltage consumption: 0,15VA
Current measurement circuit
- Nominal current (In): …/5A, …/1A, …/0.250A
- Phase current measuring range0.01…10A (…/5A),0.01…2A (…/1A), 0.01…0.5A (…/0.250A)
- Neutral current measuring range: 0.02...0.5A (.../0.250A, calculated)
- Maximum pulse current: 100 A
- Minimum current measurement: 0,01 A (…/5A, …/1A, …/0,250A
- Maximum input current consumption: 0,9 VA
- Installation category: CAT III 600 V
Measurement accuracy
- Phase voltage measurement: Class 0.2 ±1 digit (20…600 Vca, …/5A, …/1A, …/0.250A)
- Neutral voltage measurement: Class 0.5 ±1 digit (50…600 Vca, …/5A, …/1A, …/0.250A)
- Phase current measurement: class 0,2 ±1 digit 0.05…8A (…/5A),0.01…1.2A ( …/1A), 0,01 … 0,3A (…/0,250A)
- Neutral current measurement: class 1 ±1 digit 0.05…6A (…/5A),0.05…1.2A ( …/1A), calculated (…/0.250A)
- Frequency measurement: Class 0.1 (…/5A, …/1A, …/0.250A)
- Active power measurement (kW): (Vn 230/110 Vac) class 0.5 ±1 digit 0.05…6A (…/5A),0.01…1.2A ( …/1A), 0.01…0.3A (…/0.250A)
- Apparent power measurement (kVA): (Vn 230/110 Vac) class 0.5 ±1 digit 0.05…6A (…/5A),0.01…1.2A ( …/1A), 0.01…0.3A (…/0.250A)
- Reactive power measurement (kvar): (Vn 230/110 Vac) Class 1 ±1 digit 0.05…6A (…/5A),0.01…1.2A ( …/1A), 0.01…0.3A (…/0.250A)
- Active energy measurement (kWh): (IEC 62053-22) Class 0.5S (…/5A), Class 1 (…/1A), Class 1 (…/0.250A)
- Reactive energy measurement (kvarh): (IEC 62053-23) Class 1 (…/5A), Class 2 (…/1A, …/0.250A)
- Power factor measurement: class 0,5 (…/5A, …/1A, …/0.250A)
- Voltage THD: class 1 (…/5A, …/1A, …/0.250A)
- Voltage harmonics (THD): class 1 (…/5A, …/1A, …/0.250A)
- Current THD: class 1 (…/5A, …/1A, …/0.250A)
- Current harmonics (THD): class 1 (…/5A, …/1A, …/0.250A)
Field Instruments is the premier provider of instrumentation solutions for process industries and building automation in Sri Lanka. We offer a wide range of high-quality, reliable, and effective branded instrumentation, supported by exceptional customer service. Explore our extensive selection, including an impressive range of Energy meters in Sri Lanka, at fieldinstruments.lk