Delta - Delta Application Controller 6 inputs, 6 BOs Ethernet

Delta


Delta Application Controller 6 inputs, 6 BOs Ethernet - DAC-606E

Product Delta Application Controller 6 inputs, 6 BOs Ethernet
Brand Delta
Product Price 0 LKR
Datasheet Download

Description

General

The DAC-606 is a fully programmable, Native BACnet® Advanced Application Controller that either communicates on Twisted-Pair Ethernet 10-BaseT using BACnet IP and BACnet over Ethernet (DAC-606E) or an RS-485 LAN using the BACnet MS/TP protocol (DAC-606). It is designed for a wide-range of applications that have small local I/O requirements. It also supports BACstat® network sensors and other Delta LINKnet devices.

Features

  • Native BACnet firmware
  • Fully programmable in GCL+
  • Maintenance free super capacitor for real-time clock and SRAM backup on DAC-606E
  • Supports 6 BACstat network sensors on LINKnet for room sensing and control or 2 Delta Field Modules on LINKnet for I/O expansion
  • Firmware upgrade and database load/ save over the network
  • Supports Modbus® capability via flash loading in the field
  • Service port
  • Screw or DIN rail mountable LED indicator for each output, power, CPU and SCAN status

Specifications

  • Make: Delta
  • Model: DAC-606E
  • BACnet Device Profile: BACnet Advanced Application Controller (B-AAC)
  • Inputs: 11 Universal Inputs (10-bit) supporting:
      • 0-5 VDC
      • 0-10 VDC
      • 10 kΩ Thermistor
      • Dry Contact (using 10 kΩ Thermistor
      • jumper setting)
      • 4-20 mA
  • Outputs:
      • 6 Binary TRIAC Outputs (jumper configured for internal or external power)
  • Device Addressing:  Set via DIP switches and jumpers, or software setup
  • Connectors: Removable screw-type terminal connectors
  • Wiring Class: Class 2 / SELV
  • Power: 24 VAC 50/60 Hz @ 8 VA, 80 VA with fully-loaded TRIAC Outputs
  • Technology:
    • (non-Ethernet version) 16-bit processor 1 MB Flash memory 127 KB SRAM memory for database
    • (Ethernet version) 16-bit processor 2 MB Flash memory 319 KB SRAM memory for database Super Capacitor for 72-hour backup of real-time clock and SRAM
  • Communications Ports;
      • Twisted-Pair Ethernet (10-BaseT) @ 10 MB, BACnet IP, BACnet over Ethernet
      • Main LAN (NET1): BACnet MS/TP @ 9600, 19200, 38400 or 76800 bps (default), max of 99 devices per BACnet MS/TP network
      • SubLAN (NET2): Delta LINKnet @ 76800 bps, max 6 devices on LINKnet, with no more than 2 DFM devices