Space/ Wall mount Air Quality Sensors & Transmitters

Greystone IAQRM6FC Total Indoor Air Quality Sensor

Available to order MODEL IAQRM6FC

The IAQ will monitor up to 6 parameters that include Particulate Matter (PM1, PM2.5, PM4 & PM10), Volatile Organic Compounds, Carbon Dioxide, Formaldehyde, Humidity & Temperature and provide either a BACnet® or Modbus signal for connection to a building automation system. The IAQ...

Supplied by FieldInstruments.lk Sri Lanka office · global sourcing network
Delivery time Confirmed with your quotation, based on availability
Freight & applicable duties Extra. Final costs will be provided with your quotation.
Need delivery to another country? Contact us for availability and delivery options.
Contact us

General

The IAQ will monitor up to 6 parameters that include Particulate Matter (PM1, PM2.5, PM4 & PM10), Volatile Organic Compounds, Carbon Dioxide, Formaldehyde, Humidity & Temperature and provide either a BACnet® or Modbus signal for connection to a building automation system. The IAQ features field-replaceable sensor modules, a full-color capacitive touch screen LCD that’s user-configurable, and a configurable alarm relay output. All this is housed in a new modern, quick-mount enclosure.

The IAQ facilitates compliance with ASHRAE 62.1 standard for air quality and contributes toward satisfying Feature A08 and T06 under the WELL Building Standard®.

Features

  • Measures 5 or 6 parameters
  • Field replaceable sensor modules
  • BACnet® or Modbus communications
  • Full-colour configurable touchscreen LCD
  • Configurable alarm relay
  • Modern, quick-mount enclosure

Specifications

  • Make: Greystone
  • Model: IAQRM6FC
  • PARTICULATE MATTER (PM)
    • Type: Laser Scatter Method (Field Replaceable)
    • Particulate Size: PM1.0, PM2.5, PM4.0, and PM10
    • Mass Concentration Range: 0 - 1000 ug/m3 or 0 - 3000 #/cm3 (Selectable)
    • Mass Concentration Resolution: 1 (ug/m3, 1#/cm3)
    • Accuracy: PM1.0 and PM2.5 ±10 ug/m3 (0 – 100 ug/m3), ±10%M.V. (100 – 1000 ug/m3)
    • Accuracy: PM4 and PM10 ±25 ug/m3 (0 – 100 ug/m3), ±25%M.V. (100 – 1000 ug/m3)
    • Sensor Life Expectancy: > 10 years
  • CARBON DIOXIDE (CO2)
    • Type: Dual channel non-dispersive infrared (Field Replaceable)
    • Accuracy: ± (30ppm + 3% of measured value)
    • Range: 0 - 10000 ppm  
    • Auto-Cal: Selectable On (ASC) or Off (FRC)
    • Altitude Adjustment: 0 - 3000 meters
    • Calibration: Field calibration capable with calibration kit
    • Sensor Life Expectancy: > 15 years
  • VOLATILE ORGANIC COMPOUNDS (VOC)
    • Type: MOX metal oxide semiconductor (Field Replaceable)
    • Range: VOC Index  (0 - 500) or TVOC (1300 ppb or 6000 ug/m3)
    • Resolution: 1 (VOCI, PPB, ug/m3)
  • RELATIVE HUMIDITY (RH)
    • Type: Thermoset polymer-based capactiance sensor chip (Field Replaceable)
    • Range: 0 -100% RH
    • Accuracy: ±1.5% RH
    • Resolution: 0.1% RH
    • Calibration: +/- 10% Offset
  • TEMPERATURE (TEMP)
    • Type: Bipolar transistor sensor chip (Field Replaceable)
    • Range: 0 to 60°C, 32 to 140°F
    • Accuracy: ± 0.2°C, ± 0.4°F (Typical)
    • Resolution: 0.1°C/°F
    • Calibration:-5 to 5°C Offset,
    • Resolution: = 0.1°C ;-10 to 10°F Offset, Resolution = 0.1°F
  • FORMALDEHYDE (CH20)
    • Type: Electrochemical (Field Replaceable)
    • Range: 0 - 1000 ppb or 0 - 1230 ug/m3
    • Accuracy: ±10% FS@25°C
    • Resolution: 1 (ppb, ug/m3)
    • Sensor: Life Expectancy > 6 years
  • NETWORK INTERFACE
    • Hardware: MS/TP, 2-Wire, RS-485
    • Software: BACnet® or Modbus
    • Baud Rate: 9600, 19200, 38400, 57600, 76800, or 115200
    • Address Range: BACnet®: 0 - 127, Modbus: 1 - 255
  • Display: Conceled LCD