General
The IAQ will monitor up to 6 parameters that include Particulate Matter (PM1, PM2.5, PM4 & PM10), Volatile Organic Compounds, Carbon Dioxide, Formaldehyde, Humidity & Temperature and provide either a BACnet® or Modbus signal for connection to a building automation system. The IAQ features field-replaceable sensor modules, a full-color capacitive touch screen LCD that’s user-configurable, and a configurable alarm relay output. All this is housed in a new modern, quick-mount enclosure.
The IAQ facilitates compliance with ASHRAE 62.1 standard for air quality and contributes toward satisfying Feature A08 and T06 under the WELL Building Standard®.
Features
- Measures 5 or 6 parameters
- Field replaceable sensor modules
- BACnet® or Modbus communications
- Full-colour configurable touchscreen LCD
- Configurable alarm relay
- Modern, quick-mount enclosure
Specifications
- Make: Greystone
- Model: IAQRM6FV
- PARTICULATE MATTER (PM)
- Type: Laser Scatter Method (Field Replaceable)
- Particulate Size: PM1.0, PM2.5, PM4.0, and PM10
- Mass Concentration Range: 0 - 1000 ug/m3 or 0 - 3000 #/cm3 (Selectable)
- Mass Concentration Resolution: 1 (ug/m3, 1#/cm3)
- Accuracy: PM1.0 and PM2.5 ±10 ug/m3 (0 – 100 ug/m3), ±10%M.V. (100 – 1000 ug/m3)
- Accuracy: PM4 and PM10 ±25 ug/m3 (0 – 100 ug/m3), ±25%M.V. (100 – 1000 ug/m3)
- Sensor Life Expectancy: > 10 years
- CARBON DIOXIDE (CO2)
- Type: Dual channel non-dispersive infrared (Field Replaceable)
- Accuracy: ± (30ppm + 3% of measured value)
- Range: 0 - 10000 ppm
- Auto-Cal: Selectable On (ASC) or Off (FRC)
- Altitude Adjustment: 0 - 3000 meters
- Calibration: Field calibration capable with calibration kit
- Sensor Life Expectancy: > 15 years
- VOLATILE ORGANIC COMPOUNDS (VOC)
- Type: MOX metal oxide semiconductor (Field Replaceable)
- Range: VOC Index (0 - 500) or TVOC (1300 ppb or 6000 ug/m3)
- Resolution: 1 (VOCI, PPB, ug/m3)
- RELATIVE HUMIDITY (RH)
- Type: Thermoset polymer-based capactiance sensor chip (Field Replaceable)
- Range: 0 -100% RH
- Accuracy: ±1.5% RH
- Resolution: 0.1% RH
- Calibration: +/- 10% Offset
- TEMPERATURE (TEMP)
- Type: Bipolar transistor sensor chip (Field Replaceable)
- Range: 0 to 60°C, 32 to 140°F
- Accuracy: ± 0.2°C, ± 0.4°F (Typical)
- Resolution: 0.1°C/°F
- Calibration:-5 to 5°C Offset,
- Resolution: = 0.1°C ;-10 to 10°F Offset, Resolution = 0.1°F
- FORMALDEHYDE (CH20)
- Type: Electrochemical (Field Replaceable)
- Range: 0 - 1000 ppb or 0 - 1230 ug/m3
- Accuracy: ±10% FS@25°C
- Resolution: 1 (ppb, ug/m3)
- Sensor: Life Expectancy > 6 years
- NETWORK INTERFACE
- Hardware: MS/TP, 2-Wire, RS-485
- Software: BACnet® or Modbus
- Baud Rate: 9600, 19200, 38400, 57600, 76800, or 115200
- Address Range: BACnet®: 0 - 127, Modbus: 1 - 255
- Display: Viewable LCD