Honeywell - Honeywell Smartline STT850-S-0-A-AHA-13-A-00A0-00 Temperature Transmitter

Honeywell


Honeywell Smartline STT850-S-0-A-AHA-13-A-00A0-00 Temperature Transmitter - STT850-S-0-A-AHA-13-A-00A0-00

Product Honeywell Smartline STT850-S-0-A-AHA-13-A-00A0-00 Temperature Transmitter
Brand Honeywell
Product Price 0 LKR
Datasheet Download

Description

General

Part of the SmartLine® family of products, the SmartLine STT850 is a high-performance temperature transmitter offering high accuracy and stability over a wide range of process and ambient temperatures.  The SmartLine family is also fully tested and compliant with Experion ®   PKS providing the highest level of compatibility assurance and integration capabilities. SmartLine easily meets the most demanding needs for temperature measurement applications.

Features

  • Digital Accuracy up to +/- 0.10 Deg C for RTD
  • Stability up to +/- 0.01% of URL per year for ten years
  • 125 mSec update time for single input models
  • 250 mSec update time for dual input models
  • Built in Galvanic Isolation  
  • Differential/Averaging/Redundant/Split Range  measurements
  • Dual Compartment Housing
  • Sensor Break detection  
  • Comprehensive on-board diagnostic capabilities
  • Full compliance to SIL 2/3 requirements.  
  • Available with 15 year warranty
  • Supports Namur 107 Extended Diagnostics
  • Supports Namur 89 Wire break
  • Direct entry of Callendar-Van Dusen coefficients R0, α, δ and β for calibrated RTD sensors (not available on DE units)

Specifications

  • Make: Honeywell
  • Model: STT850-S-0-A-AHA-13-A-00A0-00
  • Product type : STT850 SmartLine Temperature Transmitter
  • Input type : STT850 = Universal input
  • No of Inputs : S = Single
  • Digital input : 0 = No
  • Agency Approvals : A = FM Explosion proof, Intrinsically Safe, Non-incendive, & Dustproof
  • Electronic Housing Material & Connection Type : A = Polyester Powder Coated Aluminum, 1/2 NPT.
  • Output/ Protocol : H = Analog Output : 4-20mA dc, Digital Protocol : HART Protocol.
  • Customer Interface Selections : A = Indicator : None, Config Buttons: Yes (Zero/Span only), language : none.
  • Application Software : 1 = Standard diagnostic
  • Output Limit, Failsafe & Write Protect Settings : 3 = Write Protect : Enabled, Fail Mode : High> 21.0mAdc, High & Low Output Limits : Honeywell Std (3.8 - 20.8 mAdc)

Contacts and Delivery

Fieldinstruments.lk
50/3, Angampitiya Rd, Ethul Kotte, Sri Lanka. 10100.
Phone: +94718555888 Email: info@fieldinstruments.lk