Honeywell - Honeywell Smartline STT850-S-0-A-GHB-11S-A-00A6-00-0000 Temperature Transmitter

Honeywell


Honeywell Smartline STT850-S-0-A-GHB-11S-A-00A6-00-0000 Temperature Transmitter - STT850-S-0-A-GHB-11S-A-00A6-00-0000

Product Honeywell Smartline STT850-S-0-A-GHB-11S-A-00A6-00-0000 Temperature Transmitter
Brand Honeywell
Product Price 0 LKR
Datasheet Download

Description

General

Part of the SmartLine® family of products, the SmartLine STT850 is a high-performance temperature transmitter offering high accuracy and stability over a wide range of process and ambient temperatures.  The SmartLine family is also fully tested and compliant with Experion ®   PKS providing the highest level of compatibility assurance and integration capabilities. SmartLine easily meets the most demanding needs for temperature measurement applications.

Features

  • Digital Accuracy up to +/- 0.10 Deg C for RTD
  • Stability up to +/- 0.01% of URL per year for ten years
  • 125 mSec update time for single input models
  • 250 mSec update time for dual input models
  • Built in Galvanic Isolation  
  • Differential/Averaging/Redundant/Split Range  measurements
  • Dual Compartment Housing
  • Sensor Break detection  
  • Comprehensive on-board diagnostic capabilities
  • Full compliance to SIL 2/3 requirements.  
  • Available with 15 year warranty
  • Supports Namur 107 Extended Diagnostics
  • Supports Namur 89 Wire break
  • Direct entry of Callendar-Van Dusen coefficients R0, α, δ and β for calibrated RTD sensors (not available on DE units)

Specifications

  • Make: Honeywell
  • Model: STT850-S-0-A-GHB-11S-A-00A6-00-0000
  • Product Type : STT850 Smart Temperature Transmitter
  • Universal Input : STT850
  • Input Details : S - Single
  • Digital Output : 0 - No
  • Approvals : A - FM Explosion proof, Intrinsically Safe, Non-incendive, & Dustproof
  • Electronic Housing Material & Connection Type : G
  • Housing and Material : 316 Stainless Steel (Grade CF8M)
  • Connection : 1/2 NPT
  • Lightning protection : Yes
  • Output/ Protocol : H
  • Analog Output : 4-20mA dc
  • Digital Protocol : HART Protocol
  • Customer Interface Selections : B
  • Indicator : Basic
  • Ext Zero, Span & Config Buttons : None
  • Languages : English
  • Application Software : 1 - Standard Diagnostics
  • Output Limit, Failsafe & Write Protect Settings : 1
  • Write Protect : Disabled
  • Fail Mode : High> 21.0mAdc
  • High & Low Output Limits : Honeywell Std (3.8 - 20.8 mAdc)
  • General Configuration : S - Factory Standard
  • Accuracy and Calibration : A
  • Accuracy : Standard
  • Calibrated Range : Factory Std
  • Calibration Qty : Single Calibration
  • Mounting Bracket : 0
  • Bracket Type : None
  • Material : None
  • Customer Tag : 0 - No customer tag
  • Unassembled Conduit Plugs & Adapters : A6 - 1/2 NPT 316 SS Certified Conduit Plug
  • Factory : 0000 - Factory Identification