Honeywell - Honeywell Smartline STT850-S-0-C-AHC-13S Temperature Transmitter

Honeywell


Honeywell Smartline STT850-S-0-C-AHC-13S Temperature Transmitter - STT850-S-0-C-AHC-13S

Product Honeywell Smartline STT850-S-0-C-AHC-13S Temperature Transmitter
Brand Honeywell
Product Price 0 LKR
Datasheet Download

Description

General

Part of the SmartLine® family of products, the SmartLine STT850 is a high-performance temperature transmitter offering high accuracy and stability over a wide range of process and ambient temperatures.  The SmartLine family is also fully tested and compliant with Experion ®   PKS providing the highest level of compatibility assurance and integration capabilities. SmartLine easily meets the most demanding needs for temperature measurement applications.

Features

  • Digital Accuracy up to +/- 0.10 Deg C for RTD
  • Stability up to +/- 0.01% of URL per year for ten years
  • 125 mSec update time for single input models
  • 250 mSec update time for dual input models
  • Built in Galvanic Isolation  
  • Differential/Averaging/Redundant/Split Range  measurements
  • Dual Compartment Housing
  • Sensor Break detection  
  • Comprehensive on-board diagnostic capabilities
  • Full compliance to SIL 2/3 requirements.  
  • Available with 15 year warranty
  • Supports Namur 107 Extended Diagnostics
  • Supports Namur 89 Wire break
  • Direct entry of Callendar-Van Dusen coefficients R0, α, δ and β for calibrated RTD sensors (not available on DE units)

Specifications

  • Make: Honeywell
  • Model: STT850-S-0-C-AHC-13S
  • Product type : STT850 Smart Temperature Transmitter
  • Input Type : STT850 = Universal Input
  • No of Inputs : S = Single
  • Digital output : 0 = No
  • Approvals : C = ATEX Explosion proof, Instrinsically Safe & Non-incendive
  • A - Electronic Housing Material & Connection Type :
  • Housing and Material : Polyester Powder Coated Aluminum
  • Connection : 1/2 NPT
  • Lightning protection : None
  • H - Output/ Protocol :-
  • Analog Output : 4-20mA dc
  • Digital Protocol : HART Protocol
  • C - Customer Interface Selections
  • Indicator : Basic
  • Config Buttons : Yes
  • Languages : English
  • 1-Standard Diagnostics
  • 3S - Output Limit, Failsafe & Write Protect Settings
  • Write Protect : Enable
  • Fail Mode : High> 21.0mAdc
  • High & Low Output Limits3 : Honeywell Std (3.8 - 20.8 mAdc)
  • S - General Configuration = Factory Standard

Contacts and Delivery

Fieldinstruments.lk
50/3, Angampitiya Rd, Ethul Kotte, Sri Lanka. 10100.
Phone: +94718555888 Email: info@fieldinstruments.lk