General The KYORITSU MODEL 2433R is a leakage clamp meter designed for measuring AC leakage current in electrical installations and equipment. It offers three measurement ranges: 40 mA, 400 mA and 400 A, with a minimum resolution of 0.01 mA for sensitive leakage current measureme...
General
The KYORITSU MODEL 2433R is a leakage clamp meter designed for measuring AC leakage current in electrical installations and equipment. It offers three measurement ranges: 40 mA, 400 mA and 400 A, with a minimum resolution of 0.01 mA for sensitive leakage current measurements.
The instrument features a frequency selector switch that helps eliminate the effects of harmonic components during measurement. With a maximum conductor diameter of 40 mm and a wide frequency response, the 2433R is suitable for electrical maintenance, leakage current investigation and inspection of industrial electrical systems.
Features
- Three AC current measurement ranges: 40 mA, 400 mA and 400 A
- Minimum resolution of 0.01 mA
- Frequency selector switch to reduce the influence of harmonic components
- Wide frequency response from 20 Hz to 1 kHz
- AC current measurement up to 400 A
- Maximum conductor diameter of 40 mm
- Compact and lightweight design
- Approximately 2-second response time
- Suitable for leakage current measurement and electrical maintenance
Key Specifications
- AC current measurement (50/60 Hz): 40 mA / 400 mA / 400 A
- Accuracy (40 mA / 400 mA ranges): ±1% of reading ±5 digits
- Accuracy (400 A range, 0–300 A): ±1% of reading ±5 digits
- Accuracy (400 A range, 300.1–399.9 A): ±2% of reading
- AC current measurement (WIDE): 40 mA / 400 mA / 400 A
- Wide-range accuracy (40 mA / 400 mA): ±2.5% of reading ±10 digits (20 Hz–1 kHz)
- Wide-range accuracy (400 A, 0–300 A): ±2.5% of reading ±10 digits (40 Hz–1 kHz)
- Wide-range accuracy (400 A, 300.1–399.9 A): ±5% of reading (40 Hz–1 kHz)
- Minimum resolution: 0.01 mA
- Maximum conductor diameter: 40 mm
- Frequency response: 20 Hz–1 kHz; 40 Hz–1 kHz on the 400 A range
- External stray magnetic field effect: Approximately 10 mA AC near a 15 mm conductor carrying 100 A AC
- Response time: Approximately 2 seconds
- Applicable standards: IEC 61010-1 CAT III 300 V, Pollution Degree 2; IEC 61010-2-032
- Power supply: 2 × R03 (1.5 V) batteries
- Dimensions: 185 × 81 × 40 mm
- Weight: Approximately 270 g (including batteries)
FieldInstruments.lk
International Inquiries:
Xelexon International (Pvt) Ltd
510, Level 05, Jana Jaya City, Rajagiriya, Sri Lanka 10100